AKREOS® AO PRELOADED / AKREOS® AO

CAPTURE THE ESSENCE OF YOUR PATIENTS EVERYONE’S EYES ARE UNIQUE

Benefits of the Akreos® IOLs with Advanced Optics (AO) Technology

  • Thanks to the design of their optic, they do not introduce higher-order aberrations, providing a better quality of vision 1.2
  • Uniform power from the center to the periphery of the optic, for a predictable visual outcome in all patients regardless of the shape of the cornea, size and center of the pupil or the capsular bag
  • They maintain the natural positive spherical aberration of the cornea, which may resultin a greater depth of field compared with aberration correcting IOLs3

The Akreos® platform has an aspheric design that adapts to a wide range of patients*

The optical performance of an IOL with AO technology should be better than that of a standard spherical IOL1

The Akreos® IOLs are available in a preloaded version with the BAUSCH + LOMB SimplifEYE™ delivery system.

  • Less risks of IOL damage, cross-contamination and mishandling.
  • It is thought that during the next several years, use of preloaded disposable injectors is expected to grow and may well represent the industry’s future21

 


PRODUCT INFORMATION

MATERIAL

  • Hydrophilic acrylic
  • 26 % water content
  • UV Filter
  • Refractive index: 1.46

DESIGN

  • Monofocal aberration-free aspheric optic
  • 360° posterior square edge
  • Haptic angulation 0°
  • One-piece IOL with four-point fixation
  • Orientation features to indicate the anterior side (top right and bottom left)

OPTIC DIAMETER

  • 6.2 mm: 0.00 D to +9.00 D
  • 6.0 mm: +10.00 D to +30.00 D

OVERALL DIAMETER

  • 11.0 mm: 0.00 D to +15.00 D
  • 10.7 mm: +15.50 D to +22.00 D
  • 10.5 mm: +22.50 D to +30.00 D

DIOPTER RANGE

  • D to +30.00 D
  • D to +10.00 D (increments of 1.00 D)
  • +10.00 D to +30.00 D (increments of 0.50 D)

INJECTORS

  • Hydroport™: AI-28 (1 Unit/box) | Recommended incision size: 2.8 mm (in the bag)
  • Viscoject™ 2.2 (10 Units/box) Ref: LP604340 |Recommended incision size: 2.2 mm (Wound assist technique)
  • Viscoject™ BIO 1.8 (10 Units/box) Ref: LP604350C | Recommended incision size: 1.8 mm (Wound assist technique)
  • SimplifEYETM preloaded delivery system | Recommended incision size: 1.8 mm

OPTIC CONSTANT

  • A-Constant SRK/T: 118.5
  • ACD: 5.26
  • Surgeon factor: 1.51
  • Haigis: a0: -0.83 / a1: 0.305 / a2: 0.191

ULTRASONIC CONSTANT

  • A-Constant: 118.0
  • ACD: 4.96
  • Surgeon factor: 1.22

 

Akreos® AO Brochure

Akreos® AO Preloaded Loading Guide

Akreos® AO Loading Guide Video